All-in-One Skid Air Compressor Units (10–75 HP)
Turnkey Compressor + Dryer + Tank + Filtration Station — one electrical hookup, one air discharge point, factory-integrated on a single steel skid.

Integrated PMV screw compressor, air receiver, refrigerated dryer and filtration on a single skid.
Direct Answer
An all-in-one skid air compressor station combines a PMV/VSD rotary screw compressor, vertical air receiver tank, refrigerated air dryer, precision filtration, controls and piping on one heavy-duty steel skid. AirSpace Machinery configures these turnkey units from 10 HP to 75 HP (7.5–55 kW), pressure ratings 8–13 bar, indicative FAD 1.2–9.1 m³/min, and receiver capacities 300–1,000 L.
What Is Included in an All-in-One Skid Station?
This is a pre-engineered compressed air system, not a compressor alone:
- PMV/VSD rotary screw compressor on a reinforced steel skid base — output matches changing plant demand.
- Vertical air receiver tank (300–1,000 L) — absorbs demand peaks, stabilises pressure, reduces cycling.
- Refrigerated air dryer + multi-stage precision filtration — factory pre-piped and pre-wired, tested as one system.
Air path: Compressor → aftercooling & condensate separation → receiver tank → pre-filtration → refrigerated dryer → fine filtration → single air discharge point.
Why Choose a Skid-Mounted Package?
- Installation simplicity — no separate foundations, piping, cabling or dryer connections to coordinate.
- Up to 50% smaller footprint — depending on access, service space and ventilation.
- Fewer leak points and pressure drops — compared with long runs of interconnection pipework.
- Clearer scope of supply — one RFQ covers compressor, receiver, dryer, filters, controls, skid, factory testing, export packing and documentation.
The 35% Energy Delta: A Target, Not a Guarantee
AirSpace uses The 35% Energy Delta as a project comparison framework between PMV/VSD systems and legacy fixed-speed units under variable-demand conditions. A PMV/VSD system reduces waste by slowing the motor when demand falls. Actual results depend on operating hours, load profile, pressure setpoint, leakage, electricity price and baseline equipment condition.
Technical Range — 10–75 HP Skid Compressors
| Model | HP / kW | Pressure | Indicative FAD | Tank | Dryer | Filtration |
|---|---|---|---|---|---|---|
| AS-SKID-10 | 10 HP / 7.5 kW | 8–10 bar | 1.2–1.5 m³/min | 300 L | Refrigerated | Pre + fine filter |
| AS-SKID-20 | 20 HP / 15 kW | 8–10 bar | 2.2–2.8 m³/min | 500 L | Refrigerated | Multi-stage |
| AS-SKID-30 | 30 HP / 22 kW | 8–13 bar | 3.2–4.0 m³/min | 500–700 L | Refrigerated | Multi-stage |
| AS-SKID-40 | 40 HP / 30 kW | 8–13 bar | 4.2–5.2 m³/min | 700 L | Refrigerated | Multi-stage |
| AS-SKID-50 | 50 HP / 37 kW | 8–13 bar | 5.2–6.5 m³/min | 800 L | Refrigerated | Multi-stage |
| AS-SKID-60 | 60 HP / 45 kW | 8–13 bar | 6.5–7.8 m³/min | 1,000 L | Refrigerated | Multi-stage |
| AS-SKID-75 | 75 HP / 55 kW | 8–13 bar | 7.8–9.1 m³/min | 1,000 L | Refrigerated | Multi-stage |
FAD should be compared at the stated operating pressure under a consistent test method such as ISO 1217. Final dimensions, weight, voltage, frequency and tank configuration to be confirmed via RFQ.
Typical Applications
- General manufacturing and automotive repair workshops
- Packaging lines and food packaging
- CNC machining workshops
- Textile auxiliary air
- Modular / containerised compressor rooms
- Distributed air stations close to production equipment
- Replacement of separate compressor, dryer and tank installations
FAQ for Procurement Engineers
Does the package need only one electrical connection?
The standard concept is one main electrical hookup for the integrated station. Exact requirements depend on compressor and dryer power, control voltage and local electrical standards.
What pressure options are available?
Standard planning range is 8–13 bar. The compressor, receiver, dryer, filters, valves and safety devices must all be selected for the requested operating pressure.
Can the package supply oil-free compressed air?
Yes, an oil-free configuration can be specified when required. A lubricated compressor with filtration should not automatically be treated as equivalent to a genuine oil-free design. Define the target ISO 8573-1 class in the RFQ.
How quickly can the unit be delivered?
Factory-direct delivery is typically planned within 7–35 days, depending on configuration, testing, documentation and production scheduling.
How do I verify CE and ISO 9001 documentation?
Request the applicable CE Declaration of Conformity and supporting technical documentation. Verify the manufacturer's ISO 9001 certificate scope, validity and issuing body.
Request a Turnkey Skid Compressor Proposal
Send an RFQ for a project-matched design and quotation:
- Name
- Company
- Required HP / kW
- Target Pressure (bar / psi)
- Air Demand (FAD, m³/min / CFM)
- Preferred Tank Size
- Destination Country
- Inquiry Type: New project / Factory replacement / Distributor partnership
Get a Proposal — AirSpace engineers will verify the compressor, dryer, tank, filtration, controls, dimensions, weight and electrical specification before quotation.
⚡ Is Your Factory Bleeding Cash?
Most fixed-speed compressors waste $3,600/year in "Unload Tax." Test your waste level in 30 seconds.
RUN THE ROI TEST →