Short answer: Class 0 is not a fixed number. Per ISO 8573-1:2010, Class 1 oil is limited to 0.01 mg/m³, and the Class 0 row is left for the user and supplier to agree a stricter limit in writing. EU GMP Annex 1 (2022) §6.18 requires oil and water content to be specified for gases that contact product; it does not name ISO 8573-1 or mandate an oil-free compressor. A defensible offer therefore contains a written mg/m³ limit, a named test method and a sampling point — not the word “Class 0” on its own. [1][4]
By Johnny Wayne, Managing Director, AirSpace Machinery Co., Ltd. — 20 years in industrial compressed air systems. Reviewed by our engineering team.
We manufacture oil-free screw and scroll compressors in Shanghai for pharmaceutical and food plants that need documented, auditable compressed air. When a quality manager asks us what Class 0 means, we do not answer with the label. We answer with the specification, the test method and the sampling point that EU GMP Annex 1 (2022) §6.18 expects the user to define. That is what this page sets out.
What does Class 0 actually mean — and why is the label alone not a specification?
Per ISO 8573-1:2010, purity is written as a three-part code such as [1:2:1] covering solid particles, water as pressure dew point, and total oil. The lower the number, the stricter the class. [1]
For oil, ISO 8573-1:2010 sets Class 1 at 0.01 mg/m³ total oil. The Class 0 row is deliberately open: where requirements are tighter than Class 1, the user and supplier agree the limit and record it. [1] There is no ISO-defined fixed “0.00 mg/m³” class, and claims of absolute zero oil are not supported by the standard. In our experience at audit, that distinction is exactly what a QA reviewer tests first.
So there are three questions worth asking any supplier:
| # | Question | What a defensible answer contains |
|---|---|---|
| 1 | What is the agreed Class 0 limit, in mg/m³? | A number written into the specification, not just “Class 0” |
| 2 | Which test method was used? | Per ISO 8573-2 for oil aerosol, ISO 8573-5:2025 for oil vapour [2][3] |
| 3 | Where was the sample taken? | Compressor outlet, treatment package outlet, or point of use — these give different results |
We supply these three items as part of the technical documentation package. Specific declared limits for each model are confirmed against the test report for the exact airend supplied; ask us for the current report at quotation stage. In practice, we prepare that report pack together with the machine’s flow and pressure data, so the numbers belong to the unit being offered rather than to a catalogue series.
What does EU GMP Annex 1 (2022) actually require for compressed air?
The 2022 revision of EU GMP Annex 1, Manufacture of Sterile Medicinal Products, treats gases that contact product as utilities under the Contamination Control Strategy. The relevant clauses are 6.18 to 6.20:
- §6.18 — “Gases that come in direct contact with the product/primary container surfaces should be of appropriate chemical, particulate and microbial quality. All relevant parameters, including oil and water content, should be specified, taking into account the use and type of the gas, the design of the gas generation system…” [4]
- §6.19 — “Gases used in aseptic processes should be filtered through a sterilising grade filter (with a nominal pore size of a maximum of 0.22 µm) at the point of use.” Filter integrity testing and periodic microbial monitoring of the gas at point of use are also required. [4]
- §6.20 — backflow prevention where vacuum or pressure systems could affect product. [4]
Read that carefully: Annex 1 requires you to specify and control oil and water, and to filter aseptic-process gases at point of use. It does not name ISO 8573-1, and it does not say that only oil-free compressors are permitted. Anyone telling you the annex mandates a particular ISO class is going beyond the text. [4]
Where an oil-free compressor earns its place is simpler and more defensible: the compression element adds no lubricating oil to the air stream, so one contamination source is removed at the design stage, rather than relying on downstream filters to catch oil introduced upstream. That is a risk-reduction argument, and it is the one to put in front of QA. Our engineers make the same point during commissioning: the compressor is one part of the chain, and the class must be specified at the point where the product sees the air.
Which oil-free technology fits a pharmaceutical line?
| Technology | How oil is avoided | Typical fit |
|---|---|---|
| Water-lubricated oil-free screw | Water seals and cools the compression chamber; no lubricating oil in the air end | Continuous duty, higher capacities |
| Dry oil-free screw | No oil in the compression chamber; rotors run dry | Continuous duty where water is undesirable |
| Oil-free scroll | No oil in the compression mechanism; compact and quiet | Point of use, cleanroom and laboratory supply |
Pressure dew point, filtration, piping material and point-of-use filters determine the air quality delivered to the process. Specify the class at the point of use, and hold one supplier accountable for the complete treatment package. Our oil-free packages are rated for full output at 50 °C ambient, per the published AirSpace product specification.
What documentation comes with every pharma system?
For audit readiness, the package we hand over includes:
- Written air-quality specification (particle, water and oil classes, with stated limits)
- Test reports naming the measurement method and sampling point for the supplied airend
- Material and component documentation for the treatment package: dryer, filters, receiver and piping
- IQ/OQ support documentation and a filter maintenance schedule
- CE declaration and ISO 9001:2015 factory certification details
Need a copy before you shortlist suppliers? Request the current Class 0 test report and specification template at johnnywayne@chinacompressor.org. For example, if your process specifies a limit stricter than the ISO 8573-1:2010 Class 1 value, we will show the written figure and the method used to verify it, not just the class name. [1]
Frequently asked questions
Is Class 0 the same as zero oil?
No. Per ISO 8573-1:2010, the Class 0 limit is agreed between user and supplier; it must be stricter than Class 1 (0.01 mg/m³ oil), but the standard defines no fixed value. Ask for the written limit. [1]
Does EU GMP Annex 1 require Class 0 compressors?
No. Annex 1 §6.18 requires that relevant parameters, including oil and water content, be specified for gases contacting product; §6.19 requires 0.22 µm point-of-use filtration for aseptic processes. It does not name ISO 8573-1 or mandate Class 0. [4]
Can an oil-injected compressor with good filters achieve the same result?
Filtration can reduce oil carryover, but it introduces dependent failure modes: filter loading, bypass and vapour breakthrough. An oil-free air end removes the oil source at design stage. The right choice depends on your risk assessment and the agreed specification.
What pressure dew point does pharma air need?
It depends on the process and the specified water class; per ISO 8573-1:2010, water is classified by pressure dew point. Annex 1 §6.18 requires the water content to be specified rather than prescribing one figure. [1][4]
Why work with AirSpace rather than a local distributor?
You deal with the factory directly — engineering, documentation and spare parts come from the same source. We operate a 4,000 m² facility in Shanghai, are ISO 9001:2015 certified and CE marked, and export through distributors in Vietnam, Indonesia, the Philippines, Thailand and Malaysia, among other emerging markets.
Key takeaways
- Per ISO 8573-1:2010, Class 0 has no fixed number: the limit must be written, stricter than Class 1 at 0.01 mg/m³, with a named test method and sampling point. [1]
- EU GMP Annex 1 (2022) §6.18 requires oil and water to be specified for product-contact gases; it does not mandate ISO 8573-1, Class 0 or oil-free compressors. [4]
- An oil-free airend removes one contamination source at design stage, but the delivered class still depends on dryer, filtration, piping and point-of-use filters.
- Ask for the model-specific test report before shortlisting; the figures should belong to the airend you are buying, not to a brochure.
Related pages
- ISO 8573-1 explained in under 3 minutes — what Class 0 actually means
- Pharmaceutical-grade oil-free compressed air — ISO 8573-1 Class 0 for GMP
- Oil-free scroll compressors — product range
- Oil-free air compressor hub
- Request a quotation
Sources and standards
- [1] ISO 8573-1:2010, Compressed air — Part 1: Contaminants and purity classes — https://www.iso.org/standard/46418.html (current edition; a revision project began in 2025)
- [2] ISO 8573-2:2018, Oil aerosol content — https://www.iso.org/standard/66999.html
- [3] ISO 8573-5:2025, Oil vapour content, Edition 2 published 2025-07, replacing ISO 8573-5:2001 — https://www.iso.org/standard/86791.html
- [4] EU GMP Annex 1, Manufacture of Sterile Medicinal Products (2022), §§6.18–6.20 — https://health.ec.europa.eu/system/files/2022-08/20220825_gmp-an1_en_0.pdf
⚡ Is Your Factory Bleeding Cash?
Most fixed-speed compressors waste $3,600/year in "Unload Tax." Test your waste level in 30 seconds.
RUN THE ROI TEST →Ready to See How Much Your Facility Can Save?
Fill out the form below for a Free Energy Assessment.