Short answer: Sequence two or three screw compressors as one base-load unit running at full load plus one variable-speed trim unit absorbing the swing, with setpoints 0.3–0.5 bar apart. On a three-unit station this typically cuts 25–30% of compressor kW against leaving every machine floating on its own band (based on 0.08 USD/kWh · 6,000 h/yr · average demand 14 m³/min on a 195 kW station).
By Johnny Wayne, General Manager, AirSpace Machinery Co., Ltd. — 20 years in industrial compressed air systems. Reviewed by our engineering team.
A plant that grows from one compressor to three rarely redesigns the air station; it adds a machine and leaves the pressure switches where they were. The result is a room where every unit runs a little and none runs well. Sequencing is the cheapest fix in compressed air, because it costs setpoints and a controller rather than a new machine.
How should you sequence two or three screw compressors?
Give each machine a job. One unit — the base-load — runs at full load for as long as demand is above its output. A second unit, normally the variable-speed one, trims the difference and follows demand up and down. Any further fixed-speed machine sits off until demand exceeds base plus trim, then joins as a second base step.
The order is set by efficiency, not by age or by which unit is nearest the door: the base-load is the machine with the lowest specific power at 100% load, the trim the one that turns down furthest without cycling. Get it backwards and the station still works, but it pays a penalty every hour.
Why does a fixed-speed compressor at 60% load waste more than the trim unit?
Because a fixed-speed screw compressor cannot turn down. Below its capacity it cycles between loaded and unloaded, and an unloaded screw still draws 25–35% of full-load kW to keep oil pressure and rotate the airend. So the further below full load it sits, the worse its specific power becomes.
| Load point | Fixed-speed, load/unload (typical kW/m³/min) | Variable speed (typical kW/m³/min) |
|---|---|---|
| 100% | 6.2 | 6.2 |
| 75% | 7.4 | 6.6 |
| 50% | 9.1 | 7.0 |
| 25% | 12.5 | 8.2 |
The table is the whole argument for sequencing. At 50% load a fixed-speed machine is roughly 45% less efficient than it is at full load; at 25% it is twice as expensive per cubic metre. Two machines sharing a load therefore cost more than one machine carrying it, even though the total kW looks similar on paper.
What pressure band should separate each machine’s setpoint?
Typically 0.3–0.5 bar between steps, and no more than about 1 bar across the whole station. If the bands are wider, the base-load unit never reaches full load before the next machine starts, and every unit ends up partly loaded — the exact condition the sequencing was meant to prevent.
If the bands are narrower than 0.2 bar, the units fight: small pressure changes start and stop machines several times an hour, and each start costs a current spike plus wear on the contactor. A 0.3–0.5 bar step gives each machine a clear working range and keeps total pressure inside a band the production floor will not notice.
Which unit should carry the base load — the newest or the most efficient?
The most efficient at full load, which is usually a question of specific power rather than commissioning date. A 10-year-old 75 kW machine with a clean airend and a good oil separator can still beat a new budget unit at 100% load, and it is the cheaper machine to run because it is already paid for.
What decides it is the datasheet figure at the actual discharge pressure — kW per m³/min at 8 bar, not 7 bar. Two 75 kW machines with the same nameplate can differ by 8–10% in specific power, which over 6,000 hours decides whether the controller pays for itself in a year.
How do you size the trim compressor for the swing?
The trim unit covers the difference between average demand and base-load output, plus short-term peaks, and should run at 25–30% of its rating without cycling — in practice 30–40% of total station capacity, variable speed.
Our PMV range covers 10–180 HP with permanent-magnet motors and IE4/IE5 efficiency, which is the shape of machine a trim role wants: a wide turn-down band and specific power that stays flat at part load. The PMV load profile reference shows the curve at each load point.
What does poor sequencing cost on a three-unit station?
A station we see often: 2 × 75 kW fixed-speed at 12.5 m³/min each, 1 × 45 kW PMV at 7.5 m³/min, average demand 14 m³/min swinging between 9 and 19, all three online with setpoints 0.2 bar apart at 8.3 bar.
- 75 kW unit A at 70% load, cycling: 75 × (0.70 + 0.30 × 0.30) = 59.3 kW
- 75 kW unit B at 50% load, cycling: 75 × (0.50 + 0.50 × 0.30) = 48.8 kW
- 45 kW trim idling at 30%: 45 × 0.30 = 13.5 kW
- Total: 121.6 kW for 14 m³/min = 8.7 kW/m³/min
- Sequenced instead: 75 kW unit at full load 12.5 m³/min = 75 kW, unit B off, trim at 1.5 m³/min = 13.5 kW → 88.5 kW, 6.3 kW/m³/min
- Difference: 33.1 kW, or 198,600 kWh a year at 6,000 h (based on 0.08 USD/kWh · 6,000 h/yr · 70% average demand)
At 0.08 USD/kWh that is roughly 15,900 USD a year, from changing setpoints and letting one machine carry the base. Add the 0.7 bar of excess pressure and the number grows again, because each bar above what the tools need typically costs about 7% of compressor energy.
How much receiver volume does sequencing need?
Enough to stop the trim unit chasing every valve that opens. A working rule is 10–15 seconds of station output: on a 20 m³/min station that is 3,300–5,000 L, which is why plants usually end up with two receivers rather than one large tank. Storage near the biggest intermittent load matters more than storage at the compressor.
Storage also decides whether the base unit can stay at full load: with too little of it the station swings on pressure, the trim reacts, and the base unit unloads — at which point the sequencing has stopped working. The arithmetic is in our receiver sizing guide.
When should you fit a master controller instead of pressure switches?
When there are three or more machines, or when the load pattern changes by shift. Pressure switches suit two units with a clear base-load and stable demand; beyond that a controller earns its cost by rotating the lead unit and holding the band tight.
Rotation matters: a lead unit running 6,000 hours a year while its twin runs 500 needs its airend serviced years earlier, and the station loses its spare without anyone noticing.
What did the numbers look like in a real installation?
Our Vietnamese case study is the single-machine version of the same lesson. The plant — an iron fabrication works in Ho Chi Minh City, 15,000 m² under roof, more than 200 employees, 16 hours a day — was running an ageing fixed-speed compressor with line pressure swinging ±0.5 bar and air electricity above 3,200 USD a month, plus around 850 USD a month in maintenance that was not buying reliability.
We audited the installation, then commissioned a 75 kW PMV unit at 12 m³/min into a 1,500 L receiver. Stable pressure came first; the energy number followed. Any plant adding a second or third machine should sequence it the same way — one unit held at full load, one following demand — rather than let both float. The full write-up is in the Vietnam PMV case study.
How does sequencing change in textile, ceramic, glass and cement plants?
A low-pressure air compressor for the textile / ceramic / glass / cement industry usually runs in a station of two or three units, and the load pattern decides the sequencing more than the machine does: continuous processes want the base pinned at full load, batch processes a trim with wide turn-down.
| Industry | Load pattern | Sequencing implication |
|---|---|---|
| Textile | Long continuous campaigns, many small draw points | Pin the base unit, trim small swings, keep the band tight |
| Ceramic | Spray-dryer campaigns with press peaks | Base plus trim, larger receiver at the dryer |
| Glass | Short repeated bursts all shift | Wide trim range, storage close to the mould area |
| Cement | Pneumatic conveying and baghouse pulses | Base units at full load, storage at the conveying point |
In all four, the units sit in the 15–300 HP low-pressure band at 3–5 bar, so the same rule applies: one machine at full load is cheaper than three sharing it.
Key takeaways
- One base-load at full load, one variable-speed trim is the whole principle; everything else is detail.
- Setpoints 0.3–0.5 bar apart, with no more than about 1 bar across the station.
- A fixed-speed unit at 50% load is typically 45% less efficient than at full load, because it still draws 25–35% of full kW when unloaded.
- A three-unit station can save 25–30% of compressor kW — about 15,900 USD a year on the 195 kW example (based on 0.08 USD/kWh · 6,000 h/yr).
- Storage buys the sequencing time to work: 10–15 seconds of station output, near the biggest intermittent load.
Frequently asked questions
Why do two compressors use more power than one larger machine on the same demand?
Because both carry part load, and a part-loaded fixed-speed screw compressor cycles with a high unloaded share. One machine at full load plus a small trim is typically 25–30% cheaper to run on the same demand.
How far apart should compressor pressure setpoints be?
Typically 0.3–0.5 bar per step. Closer than 0.2 bar and the units start and stop each other; wider than 1 bar across the station and no unit ever reaches full load.
Can a variable-speed compressor be the base-load unit?
It can, but it is usually the wrong choice: the wide turn-down band is worth more as trim, and a VSD held at 100% gives up the flexibility it was bought for.
Do I need a master controller for two compressors?
Not always: two units with a clear base-load and stable demand work on pressure switches. From three machines up, or where demand shifts by shift, a controller pays for itself through rotation and tighter bands.
How often should the lead unit rotate?
Weekly or monthly, so running hours stay within about 10% across the station. Without rotation the lead machine reaches its first airend service years before its twin.
Sources and standards
- ISO 11011:2013 — the compressed air energy assessment method used for the load-profile measurements behind these numbers.
- ISO 8573-1:2010 — air purity classes; sequencing decisions must not compromise the dew point the plant specified.
- ISO 9001:2015 and CE marking — held by AirSpace Machinery Co., Ltd.; certificate scans are on our downloads page.
- Our references — the PMV load profile, the receiver sizing guide and the PMV screw series.
About the author
Johnny Wayne (Wei Zhuang) is General Manager of AirSpace Machinery Co., Ltd., the Shanghai manufacturer behind ChinaCompressor.org. The company builds oil-injected and Class 0 oil-free screw compressors from 2 to 540 HP (1.5–400 kW), an oil-free scroll range of 2–51 HP, and a low-pressure series at 15–300 HP for 3–5 bar duty, from a 4,000 m² production facility with 20 years of engineering history. Products carry CE marking and ISO 9001:2015 certification, and we sell through distributors who hold the regional service relationship.
Send your station layout and load profile to sales@chinacompressor.org and we will mark which unit should carry the base load.